Electric Generator Model
Electric Generator Model Original price was: ₹700.Current price is: ₹370. (Exc. GST)
Back to products
Solar Battery Eliminator
Solar Battery Eliminator 2-12V Original price was: ₹1,000.Current price is: ₹550. (Exc. GST)

Digital LED Panel Meter

  • The Digital LED Panel Meter can handle a maximum input of 199.9mV DC and display up to 1999 counts (3-½ Digit) on an LED display.
  • In case of over-range, it will indicate “1” on display.
  • The device can take 2-3 readings per second and has an input impedance of 1 mA.
  • It requires a supply voltage of 8-12V AC or 5V DC and has a compact size.

Original price was: ₹500.Current price is: ₹250. (Exc. GST)

16 People watching this product now!
  • Pick up from the Samtech Store in Ambala

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

4-5 Days

200+

  • Warranty 1 year
  • Free 7-Day Replacement

Description

SPECIFICATIONS
Maximum Input: 199.9mV DC
Maximum Display: 1999 counts (3-½ Digit) with automatic polarity indication
Indication Method: LED display
Measuring Method: Dual-Slope Integration A/Dconverter system
Over-range Indication: 1 shown in the display
Reading Rate Time: 2-3 readings per sec.
Input Impedance: Power Dissipation: 1mA
DC Decimal Point: Selectable with short-circuit
Supply Voltage: 8-12V AC or 5V DC

 

Please follow the instructions below for the operation of the Digital LED Panel Meter:

a. If necessary, add proper voltage dividers (RA & RB are not included) and a decimal point wire jumper according to the following table:

– For DC 200mV Range, use RA = 0Ω, RB = 10MΩ and connect to P3.

– For DC 2V Range, use RA = 10MΩ, RB = 1MΩ and connect to P1.

– For DC 20V Range, use RA = 10MΩ, RB = 100kΩ and connect to P2.

– For DC 200V Range, use RA = 10MΩ, RB = 10kΩ and connect to P3.

– For DC 500V Range, use RA = 10MΩ, RB = 1kΩ and connect to P1.

– For DC 2mA Range, use RA = 0Ω, RB = 100Ω and connect to P1.

– For DC 20mA Range, use RA = 0Ω, RB = 10Ω and connect to P2.

– For DC 200mA Range, use RA = 0Ω, RB = 1Ω and connect to P3.

– For DC 2A Range, use RA = 0Ω, RB = 0.1Ω and connect to P1.

Note that RA & RB are 1/4W 0.5% Metal Film Resistors.

b. Connect an 8-12V AC power supply to the panel meter.

c. For ranges other than 200mV, input an accurate 1/2 hMax voltage generated by a calibrator (e.g. 100.0V for 200.0V range) and carefully adjust the semi-fixed resistor 201 to have the same reading on the LCD.

d. Connect the input DC voltage to be measured to IN+ and COM.

e. Connect the power to VCC+5V and VSS.

 

Specification

Overview